ELECTROSAVER
CURRENT LIMITING DEVICE / LOAD    MANAGEMENT   DEVICE

CURRENT_LIMITING_DEVICE
CLD CHANGEOVER

A fully automatic high precision system for efficient distribution of individually rationed generator power in multistoried apartments, commercial complex, etc An Advantageous and cost effective alternative to conventional manual changeovers.

Working:
The Auto Changeover Cum Current Limiter Device (CLD) allows unrestricted (metred) supply from mains. On recieving generator power, it connects the line (generally un metered) to each flat/shop in a sequence and starts monitoring its load. The generator current allotment-as factory set and sealed in each CLD per buyer's specification is available on all load circuits. Whenever the load current exceeds limit continuously, the CLD distrupts the supply for 10 secs as a warning and then automatically restores it. This repeats till overload exists. On resumption of mains, it again automatically changeover

Features:
No restriction on choice of generator power points.

CONSTRUCTION:

The automatic device panel shall be totally enclosed, metallic, rugged dust proof sleek enclosure coated with best Quality Powder Coated paint is applied  to ensure smooth and lasting  finish against corrosive and humid atmosphere.

ELECTROSAVER Automatic Load Management Device is especially designed for automatically switching the load from mains supply to Generator Supply. In Generator mode its electronic circuit will continuously monitor the load/current.  As the current value exceeds the preset value for more than 7-8 sec. (T1) , Current Limiting Device will trip the power supply for pre determined time 40-45 sec.(T2) &  then it will  switch ON the power supply again & start  Monitoring the load current again & the whole process will restart.

ELECTROSAVER Load Management Device -  Over load auto Cut off& restart Device            
with
inbuilt
TimerT1     (to surpass surge current)       ---very useful to avoid unnecessary switching---           
TimerT2    (to provide delay time in switching on the power supply after overload condition)  
---very useful to avoid relay chattering & also gives positive switching to the relay contacts   
TimerT3 --to provide time delay to avoid switching on all the ACS simultaneously.
--very useful to avoid overloading of the generator during its start up time --  

Electrosaver is provided with

  1. Solid State Current Limiting Device
  2. Auto Restart Designed For Continuous Duty
  3. Electronic Circuit ensuring positive switching of relay contact making it more reliable & durable
  4. Vacuum impregnated transformer ensures less heating, high effiency & Low Power Consumption.
  5. Every Part is Precision crafted For Durability, Efficiency and Safety.
  6. ELECTROSAVER is elegantly designed  of Powder Coated Mettalic Chasis. (rust resistive)                 
  7. Components used in Electrosaver are of branded make like KELTRON, PHILIPS, Elcon, HITACHI, Keytron, BRC, Bona.
  8. Power cable used is of glass wool fire resistant wire. Glass wool wire is used considering ever changing weather conditions from severe Hot to sever Cold & so on for  years.

Please Note : Current limiting device  can also be manufactured of any capacity /size as per requirement.

Systems are available in single & three phase models

water_level_controller